|
Medy-Air
UVC
Airborne Disinfection Device |

|
While we discuss the many
uses in the medical field. There are endless areas in today's
society that can benefit from this product. We currently have
customers outside the medical field that use the Medy-Air in daycare
centers, food preparation, veterinary industries as well as the home.
The air contaminated by the
passing people is a vehicle for infections and contagions, for both the
medical staff and the patients. Several viruses and bacteria spread in
fact through the air (i.e. tuberculosis, influenza, diphtheria, etc.). The
functional tests carried out in independent laboratories prove the
elimination of viruses, germs, moulds and spores up to 99.99%*.
Medy-Air is an innovative device for reducing the bacterial charge of the
air in environments at risk of aerial contagion, such as sterilization
rooms, dentist’s surgeries, laboratories for diagnostics and analysis,
operating theatres, first aids, etc. This device uses the well-known
properties of the UV-C germicidal radiation at 254 nanometers (UVGI) and,
specifically, the capacity of denaturing the genetic material of the cells
it strikes, by inactivating every type of microorganism present in the air
(bacteria, germs, moulds, viruses). The germicidal radiation, which is
isolated inside the device, prevents the spreading of the dangerous UV-C
rays in the environment and it eliminates any side effect detrimental to
health; the air is aspirated by the device through noiseless axial fans
and it is then submitted to an intense UV-C radiations field trough a
patented coil system; the air is purified and ready to be released into
the environment, thanks to a continuous change of air.
Medy-Air has passed strict controls that prove its effectiveness both in
microbiology laboratories and in dentist’s surgeries, medical and
veterinarian surgeries, and guarantee its full functionality and utility.
Tests were carried out by external laboratories. The effectiveness of the
sterilization through exposure to UVC rays is proved also by several
research carried out by prestigious Institutes and Universities worldwide
and by several scientific journals available from every ordinary source of
medical information; a collection of these articles and the specific
scientific documentation for the device is available on request. Medy-Air
is produced in accordance with EU laws (CE) with 12 to 36 month warranty.
|
Escherichia Coli
8.000 UFC/mc on M.H.Agar without Medy-Air
|
 |
Study performed by:
Sigla Laboratories |
Escherichia Coli
8.000 UFC/mc on M.H.Agar with Medy-Air: reduction of
bacteria is 100%
|
 |
|
| |
|
Major benefits:
1) It can be kept
working 24 hours a day regardless of the presence of persons: no
fraction of the germicidal radiation can in fact strike directly
eyes and skin, the radiation being contained inside the device;
unlike the systems with UV-C radiations towards the ceiling, this
device guarantees a total operative safety for both the staff and
the patients;
2) The UV-CHRIS -
Ultra Violet High Reflecting Coil Irradiation System is a new,
patented coil system with a concentration of ultraviolet radiations
up to four times higher compared with the standard linear flow
devices available on market. Thanks to it a 125-watt irradiation
power is applied on a generation of a linear length of more than 2.5
meters, with an exposure of the air in direct contact of the lamps
that is able to eliminate up to 99.99%* (tests show a virtual 100%)
of bacteria and viruses present in the air. This system combines
optimal performances with an incredibly small size: width 50 cm,
height 60 cm, thickness 15 cm, allowing its installation also in
sterilization rooms, dental offices, medical rooms, surgeries areas
and first aids, even with small dimensions (mobile emergency, camp
hospitals, etc).
Two noiseless axial
fans Service-Free of 120 mm with real capacity of 100 cubic meters
per hour (capacity in free air more than 300 m³/h), guarantee the
airflow for several changes of air. To insure a correct change of
air every hour, a device every 50 m³ of volume should be installed
(a 215 ft² room), multiple devices may be installed: up to 50 m3
one device, from 50 to 100 m3 two devices on two
opposite sides, from 100 to 150 m3 three devices on three
sides, etc.
3) The device only
needs electricity supply and it can be installed on the wall in few
minutes. A silencer reduces the noise made by air coming out of the
device, which is lower than an ordinary air conditioning system, so
that it is not annoying for the medical staff even in case of
continuous working conditions;
4) The continuous
change of air minimizes the bacterial charge of the environment that
does not experience alterations in the concentration of suspended
microorganisms due to the presence and to the activity of persons.
This allows critical steps such as: extraction of tools from the
autoclave into an envelope, opening and application of osteo-integrated
implants, surgical and cosmetic operations, diagnostics visits, etc.
always controlling the environmental contamination. The system
eliminates every type of virus including HIV, HBV, TBC, bacteria,
germs and microorganisms;
5) Thanks to the
patented UV-CHRIS system the irradiation is extremely effective as a
result of the direct contact with the highly efficient, not-screened
germicidal UV-C lamps, with an average distance of the air from the
point of emission of only 2.5 cm (1 inch). This "multistage
cascading system" guarantees a powerful action of the ultraviolet
rays at a close distance along a "channel" more than 2.5 meters long
(8.2 feet): the quality of the radiations and the time of exposure
ensure the destruction of all microorganisms present in the air, at
every passage;
6) An electronic
control switch allows to set times for the automatic starting and
stopping of the device, both daily and weekly: i.e. from 5.00 to
22.30, from Monday to Friday. Operations for the setting are easy
and rapid thanks to an intuitive system with LCD display and
step-by-step instructions, available in 6 different languages. A
practical control system with a lead hour-counter ensures a correct
maintenance program and consequently an optimal functioning over
time. Maintenance is minimum: a change of lamps every 8,000 hours,
with an average duration of 2 years for a day use and of 1 year for
a continuous use day/night. Lamps are easily replaced in few minutes
and original spare parts are labeled with a warranty label (the new
lamps cannot be distinguished at sight from the used ones);
7) The device does
not use any chemical substance. Size: 50x15x60H cm – Weight 25 Kg –
Maximum input 200 W - UVGI Lamps 5x25W – UV-C Output 351 hW/sec/1mt
- Air flow UV-C Irradiation 10.000 hW/sec – Air volume change
regulation: 1 fan >20 m³/h, 2 fan >50 m³/h.
|
| |
|
|
|